NR Lighting · Architectural lighting design · London & South East

Lighting design services

Lighting design services from concept to completion

NR Lighting is an independent architectural lighting design consultancy in London and the South East. I design lighting for retail, hospitality and automotive showrooms, from concept and Dialux Evo calculations through reflected ceiling plans, luminaire schedules and control narratives to Part L, LENI and BS 5266 compliance, with calculations-only appointments available UK-wide.

Last reviewed

What does an architectural lighting designer do?

An architectural lighting designer decides how a space will be lit before anyone chooses a fitting: which surfaces carry the light, what colour temperature and colour rendering the materials need, where contrast should draw the eye, and how the scheme changes through the day. The design is then proved with calculations, drawn for the contractor and checked on site.

Working independently means the specification is written around the project rather than a manufacturer’s catalogue. Luminaires are selected on photometric performance, glare control, colour quality, efficacy and buildability, and every product is checked against its IES or LDT data before it goes into a calculation model.

Concept design and lighting strategy (RIBA Stage 2)

The concept stage establishes the intent: a layered strategy for each space (ambient, accent, task and feature light), mood references, a preliminary luminaire palette and a budget allowance. It is presented so the client, architect and interior designer can picture, price and sign off the scheme before detailed design begins.

  • Lighting concept narrative and reference imagery
  • Layered strategy per space, with target illuminance and colour temperature
  • Preliminary luminaire palette and cost allowance
  • Coordination notes for the architect, interior designer and M&E engineer

Developed design and Dialux Evo lighting calculations (RIBA Stage 3)

Every scheme is modelled in Dialux Evo before it is drawn. The calculations report maintained illuminance, uniformity, unified glare rating (UGR) and installed load in W/m² against the targets in BS EN 12464-1 and the SLL Code for Lighting, with the maintenance factor assumptions stated rather than buried. False-colour plots and rendered views let the design team see what the numbers mean.

Calculations are also available as a stand-alone service for M&E consultants, electrical contractors and manufacturers who need an independent lighting report for a planning application, a BREEAM assessment or building control.

Technical design: reflected ceiling plans, luminaire schedules and specification (RIBA Stage 4)

The technical pack is what the electrical contractor prices and installs from: reflected ceiling plans and luminaire layouts in DWG and PDF, a luminaire schedule with photometric, electrical and IP data, a written specification with equal-and-approved criteria, and cove, joinery and detail drawings where light is built into the architecture. If a substitution is proposed at tender, the pack gives you the paper trail to assess it.

Lighting control narrative and scene setting

Good schemes change with the day and the trade. The control narrative sets out zoning, protocols (DALI, 0–10 V or wireless as the project warrants), scene schedules by time of day and use, daylight-linked and presence strategies, and a commissioning brief with a witness-testing checklist so the handover day finishes on time.

Part L, LENI and energy compliance

For non-domestic work in England, Approved Document L sets minimum lighting efficacy and encourages effective controls; the alternative route is the Lighting Energy Numeric Indicator (LENI) calculated to BS EN 15193-1 in kWh/m² per year. I produce the compliance evidence for building control, LENI calculations where the design relies on controls to meet the target, luminaire efficacy checks, BREEAM Hea 01 and Ene credit support, and CIBSE TM66 circularity assessments of the specified luminaires.

Emergency lighting design to BS 5266-1 and BS EN 1838

Emergency lighting is designed alongside the architectural scheme rather than added afterwards: escape-route, open-area and high-risk task-area illuminance to BS EN 1838, self-test or central-battery system selection, an emergency luminaire schedule with calculation results, and coordination with the fire strategy and signage. The aim is a scheme that passes inspection without compromising the look of the ceiling.

Tender, site and commissioning support (RIBA Stages 5–6)

Site support covers tender return review and substitution assessment, sample and mock-up review, site visits for aiming and focusing, and as-built records and O&M input. It is the stage that makes sure the built scheme looks like the drawings.

Deliverables by stage

Lighting design deliverables by RIBA stage
StageWhat I deliverWhat you get
Stage 1–2 ConceptConcept narrative, layered strategy, preliminary palette and budget allowanceA scheme you can picture, price and sign off
Stage 3 DevelopedDialux Evo calculations, false-colour and rendered views, compliance reportEvidence rather than opinion: numbers building control and assessors can check
Stage 4 TechnicalReflected ceiling plans, luminaire schedule, specification, details, control narrativeA pack the contractor can price and install from
Stage 4 CompliancePart L evidence, LENI calculation, emergency lighting design, TM66 assessmentCompliance paperwork done once, properly
Stage 5–6 SiteTender review, mock-ups, aiming and focusing, as-built recordsThe built scheme looks like the drawings

Sectors

Most of my work is retail, hospitality and automotive brand spaces, where the lighting has to sell a product, flatter a face or make paintwork read true. Each sector page explains the design targets I start from and shows the projects behind them.

  • Retail lighting design: flagships, boutiques and multi-site roll-outs
  • Automotive showroom and brand experience lighting: dealerships, VIP configuration suites and launch spaces
  • Hospitality lighting design: cafés, restaurants, bars and hotels

Standards and guidance referenced

  • BS EN 12464-1:2021: light and lighting of indoor work places (illuminance, uniformity, UGR, colour rendering)
  • SLL Code for Lighting and the CIBSE Lighting Guides (LG series)
  • Approved Document L (Building Regulations, England): lighting efficacy and controls
  • BS EN 15193-1: Lighting Energy Numeric Indicator (LENI)
  • BS 5266-1 and BS EN 1838: emergency lighting design
  • CIBSE TM66: circular economy assessment for luminaires
  • BREEAM Hea 01: visual comfort

Frequently asked questions

What do you deliver at each RIBA stage?

Concept narrative and strategy at Stage 2; Dialux Evo calculations and a developed layout at Stage 3; reflected ceiling plans, luminaire schedule, specification, control narrative and compliance evidence at Stage 4; tender review, mock-ups, aiming and as-built records through Stages 5 and 6. The table above lists each pack.

How are lighting design fees structured?

Fees are quoted per stage against a written scope, so you can appoint NR Lighting for a concept only, a full technical pack, calculations only, or site support alone. Send a brief with drawings and a programme and you will receive a proposal setting out the deliverables and fee for each stage.

Are you independent of luminaire manufacturers?

Yes. NR Lighting is a design consultancy and does not sell or supply luminaires. Products are specified on photometric performance, colour quality, glare control, efficacy and buildability, with equal-and-approved criteria so the contractor can propose alternatives that are assessed on the same basis.

Can you provide Dialux calculations only?

Yes. Calculations-only appointments are common for M&E consultants, contractors and manufacturers who need an independent lighting report: maintained illuminance, uniformity, UGR and W/m² to BS EN 12464-1, plus emergency lighting or LENI calculations where required. Supply the drawings and luminaire data and the report is returned with the model.

Do you design emergency lighting to BS 5266?

Emergency lighting is designed to BS 5266-1 and BS EN 1838 as part of the technical pack or as a stand-alone package: escape-route, open-area and high-risk task-area illuminance, luminaire schedule, system selection and calculation results for building control and the fire strategy.

Which areas do you cover?

NR Lighting is based in London and covers the South East for site work, with design-only and calculations-only appointments across the UK. International projects are welcome; recent work includes a showroom in Tokyo.